Back |
Specifications | RITS500s |
||
MEASUREMENT CAPABILITY |
Range 28ohm probe head |
25 to 62ohms | |
Range 50ohm probe head |
0 to 300ohms | ||
Accuracy 28ohm probe head |
1%
@ 50ohm 1.25% @ 62ohm 1.5% @ 28ohm * |
||
Accuracy 50ohm probe head |
1% @ 50ohm 1.25% @ 75ohm 1.5% @ 28 & 50ohm ** |
||
Testable
length 28 & 50ohm probe 28ohm probe 50ohm probe |
150mm Maximum 40mm Minimum 90mm Minimum |
||
Horizontal display resolution | 1mm | ||
Vertical display resolution | 0.03ohm | ||
* Calibrated
against traceable standards at 28, 37.5, 50 & 75ohm ** Calibrated against traceable standards at 28, 50, 75 & 100ohm |
|||
PROBING CAPABILITY |
PCB size | 330 x 630mm (max) | |
Probing area | 330 x 450mm (max) | ||
Visual programmable area | 330 x 450mm (max) | ||
Accuarcy | ±0.04mm over 300mm | ||
Repeatability | ±0.008mm (typical) | ||
Minimum pad size | 0.2mm | ||
Probing force | 142g (max) | ||
Z-axis travel | 10mm (max) | ||
Linear speed | 160mm/sec | ||
SYSTEM | Mains input | IEC inlet, 110V or 230V @ 50/60Hz, 250VA | |
Probe head | 28ohm controlled impedance | ||
Monitor | 9" monochrome with cross-hair | ||
PC REQUIREMENTS |
Pentium PC, running Windows 95, 16Mb RAM, VGA monitor, 16 bit ISA bus connector required for Custom Interface PCB, full length, 122mm height, RS232 port. | ||
PHYSICAL CHARACTERISTICS |
Operating temperature | 10oC to 30oC | |
Dimensions | 524mm high x 650mm wide x 800mm deep | ||
Weight | 90kg (approx) | ||
APPROVALS |
Conforms to applicable European Directives and is CE marked. Polar Instruments Ltd is certified to ISO 9001, LRQA Certificate no. 932134. | ||
Back |